Difference between revisions of "Coolant and Heating running temperatures"

From VW T25(T3)-Tech
Jump to navigationJump to search
Line 3: Line 3:
'''Grun:''' Haynes says thermostat fully open at 105 celsius.  
'''Grun:''' Haynes says thermostat fully open at 105 celsius.  


Bentley says:
'''Bentley says:'''
 
Begins opening at 85 C
 
Fully open 105C


Begins opening at 85 C<br>
Fully open 105C<br>
Stroke 8mm minimum
Stroke 8mm minimum


Radiator fan, carburettor engines:
'''Radiator fan, carburettor engines:'''
 
1st speed cuts in at 93 to 98 C
 
cuts out at 88 to 93 C
 
2nd speed cuts in 99 to 105 C
 
cuts out at 91 to 97 C


1st speed cuts in at 93 to 98 C<br>
Cuts out at 88 to 93 C<br>
2nd speed cuts in 99 to 105 C<br>
Cuts out at 91 to 97 C<br>


Fuel injection engines:
'''Fuel injection engines:'''


1st speed cuts in at 89 to 94 C
1st speed cuts in at 89 to 94 C<br>


cuts out at 81 C
Cuts out at 81 C<br>


2nd speed cuts in at 95 to 100 C
2nd speed cuts in at 95 to 100 C<br>


cuts out at 87 C
Cuts out at 87 C


Thermostat switch tightening torque - 30 nm (22 ft lb)
Thermostat switch tightening torque - 30 nm (22 ft lb)

Revision as of 17:46, 6 December 2009

Petrol engines

Grun: Haynes says thermostat fully open at 105 celsius.

Bentley says:

Begins opening at 85 C
Fully open 105C
Stroke 8mm minimum

Radiator fan, carburettor engines:

1st speed cuts in at 93 to 98 C
Cuts out at 88 to 93 C
2nd speed cuts in 99 to 105 C
Cuts out at 91 to 97 C

Fuel injection engines:

1st speed cuts in at 89 to 94 C

Cuts out at 81 C

2nd speed cuts in at 95 to 100 C

Cuts out at 87 C

Thermostat switch tightening torque - 30 nm (22 ft lb)

Diesel engines

(CS 1.6NA)

Coolant capacity 16 litres

1st speed cuts in at 93 to 98 C

cuts out at 88 to 93 C

2nd speed cuts in at 100 to 105 C

cuts out at 95 to 100 C

Thermostat:

Opening begins: approx 85C

Fully Open 105C

Stroke Min. 7mm

G11 phosphate free anti-freeze

Now G12 (pink) or G12 + (purple)


(JX 1.6 TD)

Forum discussion

Links

Coolant and Heating Instrumentation malfunction